City code · height and covers
Fort Lauderdale Dock Regulations for a New Dock
Fort Lauderdale dock regulations set how high a new dock can sit, not just how far out it goes. For any dock installed after March 23, 2023, the top can't be higher than the city's maximum for a tidal flood barrier at that spot, apart from two cases written in 12 inch terms.
The seawall sets the ceiling
That's the practical effect. Your dock's top elevation is tied to what the seawall there is allowed to be.
Sec. 47-19.13 is the city's tidal flood barrier standard. Its scope covers fixed structures attached to a barrier and gives mooring structures as the example, so a new dock attached to a seawall falls under it.
Covers and boathouses
No boathouse or boat cover inside the zoning setback. Nothing that isn't specifically allowed may sit in or over a public waterway.
Isle of Venice and Hendricks Isle
Owners there can dock boats past the side setback lines, under Resolution No. 85-270. Everyone else follows subsection (h), quoted on the dock builders in Fort Lauderdale page.
What the city code says on height and covers
(f) The elevation of the top surface of a dock installed after March 23, 2023, also known as the top elevation, shall not exceed the maximum elevation allowed for a tidal flood barrier at the same location, except as provided herein. Docks installed after the adoption of this ordinance that are attached to new or reconstructed tidal flood barriers and that are not constructed monolithically with the seawall cap and that do not obstruct upland surface water flow over the seawall cap may have a top elevation of up to twelve (12) inches above the maximum top elevation allowed for a tidal flood barrier. Docks installed after the adoption of this ordinance that are attached to shoreline structures, as defined in Section 47-19.13.C of the ULDR, shall not exceed twelve (12) inches above the top elevation of the existing shoreline structure to which the dock is attached.
(g) No boathouse, permanent covering, or temporary covering for a boat shall be permitted within the setback area required for the zoning district in which such shelter is to be located, nor shall any boathouse, permanent covering or temporary covering for a boat, or any other structure not otherwise specifically permitted, be permitted within or cover any public waterway.
(i) Waiver of limitations. Property owners of lands located on the Isle of Venice and Hendricks Isle may dock or anchor watercraft adjacent to their respective properties in a manner which extends beyond side setback lines, required by this section as approved by Resolution No. 85-270.
(Ord. No. C-97-19, § 1(47-19.3), 6-18-97; Ord. No. C-04-2, § 4, 1-12-04; Ord. No. C-10-44, § 2, 12-7-10; Ord. No. C-13-18, § 2, 6-4-13; Ord. No. C-16-13, § 1, 6-21-16; Ord. No. C-16-27, § 1, 12-6-16; Ord. No. C-23-05, § 1, 3-23-23; Ord. No. C-26-03, § 4, 1-20-26)
City of Fort Lauderdale Unified Land Development Regulations, Sec. 47-19.3, Boat slips, docks, boat davits, hoists and similar mooring structures, current text with history through Ord. No. C-26-03, 1-20-26: Sec. 47-19.3 on Municode. Earlier copy published by the City on Legistar: Sec. 47-19.3 (PDF). Checked November 21, 2026.
A. The purpose of the regulations in this section is to establish a consistent minimum elevation for tidal flood barriers that will:
1. Provide a standard for flood mitigation infrastructure that serves as a barrier to tidal flooding, not seepage, by accounting for water levels predicted under combined conditions of sea level rise, high tides, and storm surge through the year 2070; and
2. Ensure new shoreline structures and major shoreline improvements are designed for use as tidal flood barriers through application of consistent standards that account for future predicted tidal flood conditions and coastal water levels associated with sea level rise in accordance with current regional sea level rise projections, as updated and adopted by the Broward County Board of County Commissioners.
B. This section applies to all new tidal flood barriers, substantial repair or substantial rehabilitation to shorelines and shoreline structures, the installation of any fixed structures attached to tidal flood barriers (such as mooring structures), and existing shorelines or shoreline structures that allow intrusion of tidal waters. This section is not applicable to oceanfront beaches or shorelines seaward of the Coastal Construction Control Line.
City of Fort Lauderdale ULDR Sec. 47-19.13, Resiliency Standards for Tidal Flood Protection, current text: Sec. 47-19.13 on Municode. Adopted by Ord. No. C-23-05 (second reading March 23, 2023): ordinance text (PDF). Checked November 21, 2026.
Planning a dock on a new or raised seawall? A licensed contractor can work through both.